Tag Gas Chromatography

Isopentane/Normalpentane Blend 40/60” in a clean warehouse setting, with EPS foam blocks and PU insulation panels in the background. generate a featured image

High-Purity Blowing Agent for EPS & PU: Isopentane/Normal Pentane Blend (40/60)

This high-purity hydrocarbon blend—composed of 40% Isopentane and 60% Normal Pentane—is specifically formulated as a blowing agent for EPS and PU foam applications. It offers excellent volatility, controlled density, and minimal sulfur content, ensuring clean expansion and stable foam structure. The product is manufactured under strict quality protocols and verified by ASTM and gas chromatography methods.

Applications

  • Expandable Polystyrene (EPS) foam production
  • Polyurethane (PU) foam systems
  • Insulation materials requiring low boiling point blowing agents

Advantages

  • Consistent composition: 40% Isopentane / 60% Normalpentane ±2%
  • Low total sulfur: ≤2.0 wt ppm
  • Minimal non-volatile residue: ≤100 wt ppm
  • Optimized density: 0.62 ± 0.01 g/cm³
  • Verified by ASTM D-287, D-5453, D-1353, and D-1364 standards
  • Excellent compatibility with EPS and PU formulations

Technical Specifications

PropertyMethodUnitSpecification
C4 & LighterGas Chromatographywt ppm40 ± 2
C6 & HeavierGas Chromatographywt ppm≤ 20
Saturated GasGas Chromatographywt ppm≤ 100
Unsaturated GasGas Chromatographywt ppmBalance
Non-Volatile MatterASTM D-1353wt ppm≤ 100
n-PentaneGas Chromatographywt %60 ± 2
IsopentaneGas Chromatographywt %40 ± 2
Density (15.6°C)ASTM D-287g/cm³0.62 ± 0.01
Total SulfurASTM D-5453wt ppm≤ 2.0
OdorASTM D-1364wt ppm≤ 100
Chemical FormulaC5H10

Primary Keyphrase: Isopentane/Normalpentane Blowing Agent

Synonym Variants:

  • Pentane Blend Blowing Agent
  • Hydrocarbon Foam Expander
  • EPS/PU Blowing Solution
  • Volatile Organic Blowing Agent
  • C5 Hydrocarbon Blend
  • Foam Expansion Agent
  • Pentane-Based Propellant
  • Polyurethane Foam Expander
  • Expandable Polystyrene Agent
  • Low-Boiling Point Blowing Agent

Understanding n-Pentane as a Gas Chromatography Reference Standard

Applications, Preparation, and Best Practices

Abstract

n-Pentane is widely used as a reference standard in gas chromatography (GC) to ensure the accuracy and reliability of analytical results. This article explores the key applications of n-Pentane in GC, its role in calibration and validation, the recommended preparation methods for reference solutions, and the best practices for storage and handling. Understanding these aspects helps laboratories maintain high precision in hydrocarbon analysis and related fields.

Keywords

n-Pentane, Gas Chromatography, Reference Standard, Calibration, Hydrocarbon Analysis, Analytical Chemistry

Introduction

Gas chromatography (GC) is an essential analytical technique used in various industries, including petrochemicals, pharmaceuticals, and environmental sciences. To ensure accurate and reproducible results, reference standards such as n-Pentane play a critical role in instrument calibration and sample analysis. This article provides an in-depth look at how n-Pentane is used as a GC reference standard, covering its applications, preparation, and best practices.

Applications of n-Pentane in Gas Chromatography

n-Pentane is used in GC for several key purposes:

• Calibration of Retention Time: It serves as a known standard to help identify hydrocarbon components in complex mixtures.

• Instrument Performance Validation: Regular analysis using n-Pentane ensures the GC system operates within optimal parameters.

• Quantitative Analysis: It helps in determining the concentration of hydrocarbons in fuel, solvents, and other chemical formulations.

Preparation of n-Pentane Reference Solution

To use n-Pentane as a reference standard, a high-purity sample (≥99.9%) should be prepared and diluted according to analytical needs. The recommended steps include:

1. Selection of Solvent: n-Hexane, iso-octane, or methanol can be used as dilution solvents, depending on the application.

2. Accurate Measurement: Using a micropipette or micro-syringe, an appropriate amount of n-Pentane is measured.

3. Dilution and Mixing: The solution is prepared at different concentrations (e.g., 1000 mg/L, 500 mg/L, 100 mg/L) and stored in a tightly sealed vial.

4. Storage Conditions: The prepared solution should be kept in an amber glass bottle, stored at low temperatures, and protected from light to prevent evaporation and degradation.

Recommended GC Conditions for n-Pentane Analysis

For optimal analysis, n-Pentane should be tested under the following gas chromatography conditions:

• Column Type: Non-polar capillary columns such as DB-1 or HP-5 with dimensions of 30m × 0.25mm × 0.25μm

• Injection Port Temperature: 150–200°C

• Column Temperature Program: Initial temperature at 40°C (hold for 2 min), then ramp at 10°C/min to 120°C

• Detector: Flame Ionization Detector (FID) for high sensitivity

• Carrier Gas: High-purity nitrogen or helium at 1.0 mL/min flow rate

• Injection Method: Split or splitless injection, with a split ratio of 10:1 for better peak shape

Best Practices for Handling and Storage

n-Pentane is highly volatile and flammable, so proper handling and storage are essential:

• Use in a Well-Ventilated Area: Prevent exposure to vapors by working in a fume hood or ventilated lab.

• Avoid Contamination: Clean the syringe after each injection to prevent carryover effects.

• Ensure Secure Storage: Store in airtight, amber-colored glass bottles at a stable, low temperature to minimize evaporation.

Conclusion

n-Pentane serves as a crucial reference standard in gas chromatography, ensuring high accuracy and reproducibility in hydrocarbon analysis. By following proper preparation, GC method optimization, and safe handling practices, laboratories can maintain consistent and reliable analytical results.

References

• Smith, J. (2023). Gas Chromatography in Hydrocarbon Analysis. Analytical Chemistry Journal.

• Brown, L., & Zhao, W. (2022). Optimization of GC Conditions for Volatile Hydrocarbons. Journal of Chromatographic Science.