What is the difference between EPS fire resistance levels A, B, and B1?

What is the difference between EPS fire resistance levels A, B, and B1?

The difference between EPS fire resistance grades A, B, and B1:

  1. Fire resistance coefficient: Class A is non combustible; Level B is further divided into three levels, with B1, B2, and B3 having different levels of combustion.
  2. Flammability: Class A has zero flammability;, B1 is flame retardant, B2 is flammable, and B3 is flammable.
    At present, the common A-grade products in the market include phenolic aldehyde, rock wool, insulation mortar, foam ceramics, foam glass, and foam concrete. At present, the most advantageous A-grade material is foamed concrete, also known as foamed cement.
    EPS polystyrene board itself is a flammable material, so it is not a fireproof material in terms of fire rating. So it’s not at all A-level or B1 level. The fire resistance rating of polystyrene boards on the market is only B2 (flammable) and B3 (flammable).
    Extended Information:
    EPS physical and mechanical properties:
  3. Density
    The density of EPS is determined by the expansion ratio of polystyrene particles during the forming stage, which is generally between 10 and 45kg/m3. As EPS used in engineering, its apparent density is generally between 15 and 30kg/m3.
    At present, the density of EPS used as lightweight filling material in road engineering is 20kg/m3, which is 1% to 2% of that of ordinary road filling material. Density is an important indicator of EPS, and its mechanical properties are almost directly proportional to its density.
  4. Deformation characteristics
    When the confining pressure exceeds 60KPa, the yield strength significantly decreases, which is clearly different from the variation law of the soil. When axial strain ε When a ≤ 5%, regardless of the confining pressure, the volumetric strain ε V is close to axial strain ε a. The lateral deformation of EPS is small, which means the Poisson’s ratio is small.
    To minimize post construction settlement, after laying the EPS material layer, fill 1.2m of soil on it for preloading. The average compressive settlement of the EPS material layer is 32mm, and it can be calculated that the elastic modulus of EPS is 2.4MPa, and the EPS material is still in the elastic deformation stage.
  5. Self-reliance
    The self-sustaining nature of EPS is very beneficial for the stability of high slopes. Due to the small lateral pressure generated by the vertical compression of EPS, the use of EPS as filling material for the roadbed at the bridge head can greatly reduce the soil pressure behind the abutment, which is very beneficial for the stability of the abutment.
    The friction coefficient f between EPS block and sand is 0.58 (dense)~0.46 (loose) for dry sand and 0.52 (dense)~0.25 (loose) for wet sand; The range of f between EPS blocks is between 0.6 and 0.7.
  6. Water and temperature characteristics
    The closed cavity structure of EPS determines its good insulation performance. Its biggest characteristic when used as insulation material is its extremely low thermal conductivity, with various specifications of EPS boards having thermal conductivity ranging from 0.024W/m.K to 0.041W/m.K. EPS is a thermoplastic resin that should be used below 70 ℃ to avoid thermal deformation and strength reduction.
    Simultaneously utilizing this feature, electric heating wire processing can be used. Flame retardants can be added in production to form flame retardant EPS. Flame retardant EPS extinguishes itself within 3 seconds after leaving the ignition source. Due to the much lower bulk density of EPS compared to soil, the 1% to 10% increase in bulk density caused by water absorption can have negligible impact on engineering.
  7. Durability
    EPS has stable chemical properties in water and soil, and cannot be decomposed by microorganisms; The cavity structure of EPS also makes water infiltration extremely slow; If exposed to ultraviolet radiation for a long time, the surface of EPS will change from white to yellow, and the material will appear brittle to some extent; EPS has stable properties in most solvents, but can be dissolved in organic solvents such as gasoline, diesel, kerosene, toluene, acetone, etc. This indicates that EPS fillers require a good protective layer.

    Reference Source: JUNYUAN PETROLEUM GROUP – EPS Blowing Agent Department (Folystyrene Foam)

Expandable polystyrene (EPS)

Revolutionary patented polystyrene production method

Expandable polystyrene (EPS) consists of polystyrene micro-pellets or beads containing a blowing agent and other additives for foaming. We have developed a continuous production process in which the blowing agent is directly injected into the melt, combined with subsequent underwater pelletization.

Commercial EPS is manufactured with the addition of a blowing agent, typically a chlorinated hydrocarbon or a low-boiling petroleum-derived agent with the presence of pentane. These substances are highly flammable; by reducing the amount of flame retardant due to the addition of gypsum, they ignited during the flame propagation test, increasing the burn rate of the GPS.

Main benefits

  • The patented EPS process is economical, compact, and easy to operate
  • Continuous process for consistent product quality
  • Dispersing a wide range of additives and pigments is possible
  • Minimized waste production
  • Reduction of wastewater and process water
  • Recycling possibility for waste EPS pellets/beads/foam
  • Process allows developing innovative applications

Main applications

  • Expandable Polystyrene

EPS Panel

The self-extinguishing, fire-retardant EPS Panel foam is manufactured from 100% virgin bead and oven-cured after manufacture to ensure the resulting blocks are completely dry and free from all residual pentane.

EPS Panel is a lightweight, CFC-free, non-brittle, closed cell insulator with more consistent thermal performance over time. It has a high dimensional stability and low water vapor transmission.

A special chemical coated to the Expanded Polystyrene beads (raw material) distinguished it from standard/common EPS Panel. Fire-Retardant EPS Panel is a self-extinguishing, non-combustible material.

Fire-retardant EPS Panel with a density of 15 kg/m3 is used for clean rooms, food processing facilities and modular buildings, while the 20 kg/m3 is used for industrial and commercial cold storage.

Core

Width (cover mm)
Thickness (mm)
Length
Exterior Facing Skin
Internal Facing Skin
Standard Colors
Joint System
Finishes
Type of SkinEPS
(Expanded Polystyrene)
1,160
50, 75, 100, 125, 150, 200, 250
Up to 12 meters
0.5mm, 0.6mm G300 CRP Steel
0.5mm, 0.6mm G300 CRP Steel
Off White
Slip Joint
Plain, Ribbed, Diamond
Anti Bacterial (AB)
Food Grade (FG)
Xterior Roof and Wall (XRW)

Features and Advantages

  • Fire retardant
  • Meets safety requirements
  • Energy saving
  • Longer lifetime
  • Resistant to termites and rodents
  • Customized design
  • Easy to install saving cost of installation time
  • High performance on insulated panel
Request a Quote

Request a Quote

for Pentanes, Hexanes, Heptanes, Butanes and more

I will be back soon

Request a Quote
If you would like to receive a quote to purchase a product or you would like more information, please message us on WhatsApp.